  • Study compares intracranial aneurysm treatment with Pipeline Flex vs Classic
  • Flex associated with reduced procedure/fluoroscopy time, radiation exposure, contrast use

 

The second-generation Pipeline device, known as the Flex, improves upon the Classic design, offering greater ease of use and superior procedural outcomes. Details on its performance were published online March 9, 2016, ahead of print in the Journal of NeuroInterventional Surgery.

Elizabeth J Le, MD, of the University of Maryland Medical Center (Baltimore, MD), and colleagues compared procedural outcomes between 2 groups:

  •          38 of the first 40 consecutive patients who underwent intracranial aneurysm treatment using the Pipeline Flex (Covidien)
  •          58 of the most recent 60 consecutive patients treated using the Pipeline Classic (Covidien)

“Some of the frequently encountered issues during Pipeline Classic placement include difficulty freeing the distal end of the device from a constraining capture coil, limited pushability of the delivery wire, and inability to resheath the Pipeline after partial deployment,” Dr. Le told WLNCMD in an email.

“The second-generation Pipeline Flex contains a completely redesigned delivery system, while leaving the implantable device unchanged,” she explained. “The proximal portion of the flow diverter was placed on a resheathing pad to allow for recapture and repositioning of the device after partial deployment.

“Furthermore, the distal capture coil was replaced by 2 constraining Teflon [PTFE] sleeves, which allow for increased readiness of device opening and facilitation of stent resheathing by 180-degree rotation upon device recapture,” Dr. Le continued. “Finally, the pusher wire was exchanged for a larger, more robust laser-cut hypotube to enhance pushability of the device during delivery.” The new device is already in widespread use nationwide.

Both groups of patients were similar with respect to age, gender, and location of target aneurysms. Use of the Pipeline Flex was associated with decreased procedure and fluoroscopy time as well as reduced radiation exposure and contrast usage (table 1). All these factors remained significantly different between the 2 devices on multiple regression analysis.

 


In addition, the rate of device deployment failure was lower with the Flex device compared with the Classic device (7.1% vs. 23.9%, P = .034).


Tips for Successful Use of Flex

While the redesigned Pipeline is an improvement, Dr. Le said, “there are occasionally cases where the distal stent does not open immediately, and the guidewire does not appear to be travelling as expected. If this occurs, the device may be recaptured with the microcatheter in order to evert the PTFE sleeves or place them underneath the device, which removes their potential contribution to non-expansion of the device.” She also recommended being careful when redeploying the device after resheathing as well as not doing resheathing too often because the leading edge will no longer be protected by the PTFE and may be damaged.

While the Flex device is considered to be a superior device to the Classic, Dr. Le mentioned there may be cases when the Pipeline Classic might be preferable, such as during treatment of distal vessels that may not be able to accommodate the PTFE sleeve or tolerate the further pushing of the delivery wire needed with the new device.


Source:

  • Le EJ, Miller T, Serulle Y, et al. Use of Pipeline Flex is associated with reduced fluoroscopy time, procedure time, and technical failure compared with the first-generation Pipeline embolization device. J NeuroInterv Surg. 2016;Epub ahead of print.

 

Disclosures:

  • Dr. El reports no relevant conflicts of interest.

 

 

 

 

Monday, October 26 2020

Stroke rates for the balloon-expandable device far exceeded those of the Evolut R; conscious...

Read More »

Monday, October 26 2020

Safety goals were met in the trial, but better efficacy may require ensuring complete coverage of...

Read More »

Wednesday, September 23 2020

The findings “reinforce that this is absolutely the right thing to do and that we need to set up...

Read More »

Tuesday, July 21 2020

Whether COVID-19 adds risk by virtue of being a comorbidity or due to direct effects is unknown. A...

Read More »

Friday, May 8 2020

In some cases, large strokes are the first presentation of COVID-19 in younger patients, but...

Read More »

Monday, April 6 2020

Clopidogrel added to rivaroxaban and aspirin increased bleeding with no added protection from limb or...

Read More »

Monday, April 6 2020

Although rivaroxaban patients had more bleeding, the events were not severe and none were...

Read More »

Monday, April 6 2020

The strokes do not appear related to valve thrombosis or structural degeneration, but rather to...

Read More »

Thursday, January 23 2020

A fundamental unanswered question is whether any type of oral anticoagulation is needed in the...

Read More »

Monday, January 6 2020

Though periprocedural results look good, there are some questions about its rapid rise when...

Read More »

Wednesday, August 21 2019

In addition, an infarct in a new territory did not emerge as an independent predictor of...

Read More »

Wednesday, August 21 2019

The procedure—a hybrid of surgical and endovascular techniques—offers low stroke rates and a short...

Read More »